First, the operation steps1. Check the entire column of plates, there must be no other pills or debris.
2. Pour the granules into a dish, not too full.
3. Insert the feeding tube into the plastic bag.
4. Adjust the height of the lifting plate.
5. Turn on the power switch and check whether the sensitivity display is normal (refer to troubleshooting for sensitivity adjustment).
6. Set the quantity, if you count, please set it to more than 1000 capsules.
7. Numbers return to zero.
8. Turn on the vibration switch, adjust the vibration, and pay attention to whether the pills on the whole plate are arranged in order one by one, so as not to overlap.
9. When one side of the pill is counted, the other side will be automatically counted.
10. During the operation, please pay attention to whether the sensitivity shows whether the light flashing is normal, and at any time sampling, if there is any abnormality, it should be stopped immediately for inspection.
11. During operation, the granules should not be poured into the dish too much at a time, so as to avoid the overlap of the entire column of tracks and the inaccurate counting.
12. Avoid placing it in windows, outdoors, or in sunlight.
Machine parametersSpecifications YL-2A
Dimensions 42.7x32.7x52.5cm
Voltage 110-220V 50HZ-60HZ
Weight 20kg
Power 100W
Production 500-1500